DESCRIPTION:

Laminar flow hoods, also known as clean benches, provide filtered airflow across the work area to prevent sample contamination. These hoods are suitable for various applications that require a sterile environment and clean air, such as medical and research laboratories, sterile equipment assembly, and electronic device assembly.

Laminar flow hoods typically have either horizontal or vertical airflow. In vertical flow hoods, clean filtered air flows downward from the filter surface on top to the work surface. In horizontal laminar flow cabinets, clean air travels from a filter located behind the work surface towards the operator. The airflow direction is influenced by the procedure type, operator safety, and clearance requirements.

Esco Multi-Zone ART Workstations are vertical airflow laminars that provide filtered air from the top of the workstation towards the working surface for the most optimal safety assurance.

Multi-Zone ART Workstations have been enhanced with the integration of MIRI® chambers. These chambers are designed to provide a consistent culture environment and quick parameter recovery, making them a superior choice for keeping embryos safe.

 

FEATURES:

Multi-zone heating system
  • Multiple independent heating zones, each with its own heating elements and sensors.
  • A heated glass seat can guarantee a continuous power supply to ensure temperature control.
4 temperature settings
  • You can turn on all zones, turn off the right zone, turn off the right and middle zone.
Possibility to install a microscope
  • It provides integration with the most popular stereoscopic and inverted microscopes.
Humidification system
  • Built-in humidification system with digital control.
  • The gas outlet port is located on the table surface; a plastic cover helps to keep samples under controlled conditions.
Touchscreen monitor
  • The full-featured Windows PC with a touchscreen provides access to up-to-date information on all parameters of the work area, such as temperature and pressure readings.
Optional three-gas mixer
  • The workstations operate on pre-mixed gas, but an optional gas mixer can be installed to adapt the three-gas system.
Accessories
  • MIRI chamber can be integrated for embryo safety and improved workflow quality.
  • Optional UV lamp for work area disinfection with optional polycarbonate front cover for radiation protection.

Download the brochure

 

Recommended List of Microscopes and Base Stands:

  • INVERTED MICROSCOPE FOR MP SERIES WORKSTATION ONLY
  • Olympus IX83P1ZF: One-Deck
  • Olympus IX73P1F: One-Deck (Customization on workstation needed)
  • Olympus IX73P2F: Two-Decks
  • Olympus IX53P1F: One-Deck (Customization on workstation needed)
  • Nikon Ti-U
  • Nikon Ti-S
  • Nikon Ti-E
  • Zeiss Axio Vert.A1
  • Zeiss Axio Vert.A1 FL
  • Zeiss Axio Vert.A1 FL-LED